Oil-immersed Earthing Transformers-35kV 66kV

  • Oil-immersed  Earthing Transformers-35kV 66kV
Key attributes
Brand Vziman
Model NO. Oil-immersed Earthing Transformers-35kV 66kV
Rated voltage 35kV
Rated frequency 50/60Hz
Series JDS
Product descriptions from the supplier
Description

66kV Oil-immersed Earthing Transformers Description

The 66kV oil-immersed earthing transformers are usually used in a power system without neutral point, to provide an artificial neutral connection for earthing directly or via an impedance such as an arc suppression reactor, a resistor, a current-limiting reactor and so on.The earthing transformers may adopt a secondary (low-voltage winding) for continuous use as a power supply for the substation station.

66kV Oil-immersed Earthing Transformers Features

  • Low zero-sequence impedance
  • High magnetizing impedance
  • Low loss level, low noise
  • Long service life

66kV Oil-immersed Earthing Transformers Technical Specifications

  • Insulation Type:Dry-type/Oil-immersed
  • Type :6kV~35kV/6kV~66kV
  • Voltage Scope:100kVA~3800kVA/100kVA~5700kVA
  • Capacity Range:-25°C ~ +45°C/-45°C ~ +45°C
  • Environmental Temperature:-45°C ~ +45°C/-45°C ~ +45°C
Documentation Resource Library
Vziman IEC/ ANSI HV Grounding Transformer selection catalog
Restricted.
Vziman IEC/ ANSI HV Grounding Transformer selection catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: Can 66kV oil-immersed earthing transformers be used in conjunction with arc suppression coils?
A:

Yes, they are often used in tandem with arc suppression coils. The earthing transformer provides a stable neutral point, while the arc suppression coil compensates for the capacitive current of the system, effectively extinguishing arc grounding faults and reducing fault damage.

Q:What is the altitude limit for 66kV oil-immersed earthing transformers during operation?

A:The standard altitude adaptability is generally within 1000m. For applications above 1000m, the insulation performance and heat dissipation structure need to be specially designed to ensure stable operation under low air pressure conditions.

Q:Why choose an oil-immersed structure for 66kV earthing transformers instead of a dry-type one?

A:The oil-immersed structure offers excellent insulation performance and heat dissipation capacity, which is more suitable for the high-voltage 66kV grade. It has strong overload resistance, good sealing performance, and can adapt to harsh operating environments, making it ideal for long-term outdoor operation.

Q: What safety protection devices are equipped with 66kV oil-immersed earthing transformers?

A:Typical safety devices include pressure relief valves, gas relays, temperature controllers, and oil level gauges. These devices monitor parameters such as internal pressure, gas accumulation, temperature, and oil level in real time, and trigger alarms or tripping actions to prevent catastrophic failures.

Related Products

Related Solutions

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.