| Brand | Vziman |
| Model NO. | 10kV Silicon Steel Core Oil immersed Transformer |
| No-load loss | 200W |
| No-load current | 0.88% |
| Series | S13-M |
Oil Immersed Distribution Transformer
Product Introduction
Oil immersed transformers have stable and reliable insulation performance, effectively avoiding voltage fluctuations and interference. They have strong overload capacity, small size, light weight, and low operating noise. Not only are they easy to transport and install, but they can also reduce production and operating costs. They are high-performance distribution transformers.
1. Windings
The high and low voltage coils are wound using copper conductors, copper foil, and insulating materials. After being preheated and dried, they undergo vacuum drying in a vacuum drying device to remove moisture and gas from the insulation.They exhibit strong resistance to short-term overload.
2. Insulation
Between the layers of high and low voltage windings, pure natural wood fiber modified point glue paper is used, which can operate safely at 130°C; after winding completion, it undergoes thermal setting, forming a solid and rigid whole; The core body adopts a hybrid insulation system, with overall spacer blocks compressed to ensure the oil passages are unobstructed while enhancing the tight fit between the windings, core, and clamps. The core body is equipped with a positioning structure to prevent displacement during transportation. Additionally, all fasteners are fitted with lock nuts to ensure they do not loosen during long-term operation, meeting the requirement of a non-suspended core.
3. Core
The core utilizes high-quality, high-permeability, cold-rolled grain-oriented silicon steel sheets, with their surfaces covered by anti-corrosion insulating coatings. The silicon steel sheets undergo a 45-degree full oblique shear, and the joints between the core column and the yoke adopt a 7-step laminated structure. Simultaneously, the flatness of the silicon steel sheets is enhanced, and appropriate clamping force is applied to the iron core, effectively reducing transformer noise.
Product Standards
IEC 60076 - Power transformers – Part 1: General; Part 2: Temperature rise; Part 3: Insulation levels, dielectric tests and external clearances in air; Part 4: Guide to lightning-impulse and switching-impulse testing; Part 5: Ability to withstand short circuit; Part 7: Loading guide for oil-immersed power transformers; Part 10: Determination of sound levels; Part 20: Energy efficiency for liquid-immersed power transformers.
IEC 60214 - Tap-changers – Part 1: Performance requirements and test methods; Part 2: Application guide
IEC 60437 - Radio interference test on high-voltage insulators
IEC 60507 - Artificial pollution tests on high-voltage insulators to be used on a.c. systems
IEC 60137 - Insulated bushings for alternating voltages above 1 000 V
IEC 60404-1 - Magnetic Materials classifications
ANSI C57 12.90 - Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEC 60296 - Fluids for electrotechnical applications – Unused mineral insulating oils for transformers and switchgear
EN 50464-4 - Three-phase oil-immersed distribution transformers 50 Hz, 50 kVA to 2 500 kVA – Part 4: Requirements and tests for higher-loss transformers (HL) and higher-loss-high-short-circuit transformers (HLH)
10kV S13-M-30~2500/10 Transformer Technical Data
| Model | No-load Loss(W) | Short-circuit Impedance(%) | No-loadCurrent(%) | Total Weight(kg) | Oil Weight(kg) | Dimensions (mm) | Track Gauge (Transverse × Longitudinal) | ||
| Length | Width | Height | |||||||
| S13-M-25/10 | 90 | 4 | 1.2 | 243 | 60 | 680 | 500 | 860 | 300×400 |
| S13-M-50/10 | 130 | 1.04 | 307 | 67 | 725 | 630 | 865 | 300×400 | |
| S13-M-63/10 | 150 | 0.96 | 360 | 78 | 730 | 640 | 890 | 300×400 | |
| S13-M-80/10 | 180 | 0.96 | 427 | 85 | 755 | 690 | 920 | 400×500 | |
| S13-M-100/10 | 200 | 0.88 | 513 | 95 | 765 | 710 | 930 | 400×500 | |
| S13-M-125/10 | 240 | 0.88 | 593 | 110 | 795 | 740 | 945 | 400×500 | |
| S13-M-160/10 | 280 | 0.8 | 680 | 125 | 835 | 790 | 980 | 400×500 | |
| S13-M-200/10 | 340 | 0.8 | 787 | 140 | 1130 | 770 | 1010 | 400×500 | |
| S13-M-300/10 | 450 | 0.72 | 1020 | 178 | 1250 | 880 | 1070 | 550×660 | |
| S13-M-315/10 | 480 | 0.72 | 1607 | 180 | 1300 | 900 | 1070 | 550×660 | |
| S13-M-400/10 | 570 | 0.64 | 1293 | 206 | 1325 | 915 | 1095 | 550×660 | |
| S13-M-500/10 | 680 | 0.64 | 1507 | 235 | 1450 | 1020 | 1140 | 550×660 | |
| S13-M-630/10 | 810 | 0.48 | 1733 | 270 | 1540 | 1100 | 1150 | 660×820 | |
| S13-M-800/10 | 980 | 5 | 0.48 | 2093 | 310 | 1580 | 1120 | 1190 | 660×820 |
| S13-M-1000/10 | 1150 | 0.48 | 2387 | 354 | 1610 | 1150 | 1250 | 660×820 | |
| S13-M-1250/10 | 1360 | 0.4 | 2840 | 420 | 1660 | 1190 |
1300
|
660×820 | |
| S13-M-1500/10 | 1500 | 6 | 0.4 | 2890 | 490 | 1680 | 1200 | 1380 | 820×820 |
| S13-M-1600/10 | 1640 | 0.4 | 3387 | 510 | 1710 | 1210 | 1430 | 820×820 | |
| S13-M-2000/10 | 1940 | 0.32 | 4160 | 600 | 1810 | 1300 | 1450 | 820×820 | |
| S13-M-2500/10 | 2290 | 0.32 | 4840 | 684 | 1930 | 1400 | 1530 | 820×820 | |
| S13-M-3000/10 | 2800 | 7 | 0.65 | 4400 | 900 | 2000 | 1500 | 1800 | 820×820 |
| S13-M-3500/10 | 3200 | 0.60 | 4700 | 950 | 2080 | 1550 | 1850 | 820×820 | |
| S13-M-4000/10 | 3600 | 0.55 | 5200 | 1000 | 2150 | 1650 | 1950 | 820×820 | |
| S13-M-5000/10 | 4200 | 0.50 | 5900 | 1150 | 2450 | 1800 | 2050 | 820×820 | |
The data listed in the table above is for reference only, and the final data shall be subject to actual production.
A 10kV oil-immersed power transformer is a type of electrical transformer that operates at 10,000 volts. It uses oil for insulation and cooling. This design helps keep the transformer running efficiently while also protecting it from overheating. These transformers are commonly used in power distribution systems.
Q:How does an 10kV oil-immersed power transformer work?
A:10kV oil-immersed power transformer work by using electrical currents to create a magnetic field that transfers energy between the high and low voltage wires. The oil inside helps cool the transformer and insulates the electrical parts, keeping everything safe and functioning properly.
Q:What are the benefits of using an 10kV oil-immersed power transformer?
A:10kV oil-immersed power transformer offer several benefits, including better cooling, reduced noise when operating, and a design that minimizes electrical interference. They are also smaller and lighter than some alternatives, making them easier to install.
Q:What materials are used in the windings of a 10kV oil-immersed power transformer?
A:The windings in a 10kV oil-immersed power transformer are typically made of copper or aluminum wire. This wire is insulated to prevent electrical shorts and help maintain safety in operation. The choice of materials helps ensure the transformer can handle its electrical load.