Three Phase Oil Immersed On-Load Tap-Changing Power Transformers 35kV 38.5kV

  • Three Phase Oil Immersed On-Load Tap-Changing Power Transformers 35kV 38.5kV
Key attributes
Brand Vziman
Model NO. Three Phase Oil Immersed On-Load Tap-Changing Power Transformers 35kV 38.5kV
Rated capacity 8000kVA
No-load loss 7.38W
Series SZ-11
Product descriptions from the supplier
Description

Oil Immersed On-Load Power Transformers Product Overview

Three Phase Oil Immersed On-Load Power Transformers are core equipment in modern power transmission and distribution systems, widely applied in industrial parks, urban power grids, and large-scale energy projects. Characterized by reliable operation, strong load-bearing capacity, and excellent thermal stability, these Three Phase Oil Immersed  Power transformers adopt an oil immersed insulation structure and on-load tap-changing technology, which enables them to adjust the output voltage smoothly without interrupting the power supply. The oil immersed design effectively dissipates heat generated during operation, ensuring the transformer maintains stable performance even under long-term full-load conditions. As a key link connecting different voltage levels, Three Phase Oil Immersed On-Load Power Transformers play an irreplaceable role in improving power supply quality, optimizing power grid operation efficiency, and ensuring the safe and continuous supply of electricity to end-users.
  • Installation Type: Outdoor
  • Ambient Temperature: Maximum +40°C, Minimum –25°C
  • Altitude: Up to 1,000 m above sea level
  • Relative Humidity: ≤90% at +25°C
  • Installation Environment: Free from corrosive gases and heavy pollution
  • Primary Applications: Industrial power systems and transmission & distribution projects

Oil Immersed On-Load Power Transformers Structural Features

  • The SZ11 Oil Immersed on-load tap-changing power transformer is a newly developed product designed in response to market demands, with reliability as the top priority. It features low losses, excellent performance, reliable operation, and stable output voltage, making it especially suitable for areas or applications where grid voltage fluctuates significantly.
  • Three-Phase Oil Immersed On-Load Power Transformers feature reliable on-load voltage regulation capability, which can adjust the tap position smoothly without interrupting power supply, effectively stabilizing the output voltage and adapting to the fluctuation of grid load.
  • Three-Phase Oil Immersed On-Load Power Transformers have strong environmental adaptability, and their sealed oil tank structure can resist the erosion of harsh environments such as humidity, dust and salt mist, making them suitable for various application scenarios including industrial parks, mining areas and coastal power grids.

Oil Immersed On-Load Power Transformers Compliance Standards

  • GB 1094.1 & GB 1094.2–2013: Power Transformers
  • GB 1094.3–2003 & GB 1094.5–2008: Power Transformers
  • GB/T 6451–2015: Technical Parameters and Requirements for Oil-Immersed Power Transformers
  • IEC 60076-2、IEC 60076-3、IEC 60076-5

Oil Immersed On-Load Power Transformers Model Designation and Its Meaning

Rated Capacity (kVA) Voltage Combination Connection Group Designation No-Load Loss (W) Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%) Weight (T)
High Voltage (kV) Low Voltage (kV) Oil Weight Total Weight Added Oil Weight
SZ11-1600/35

35 ±

3x2.5%

38.5±

3x2.5%

11

10.5

6.6

6.3

Yd11 1.7 17.5 6.5 1.10 1.9 6.55 0.45
SZ11-2000/35 2.2 19.2 6.5 1.00 2.14 7.4 0.56
SZ11 -2500/35 2.55 20.6 6.5 1.00 2.3 8.5 0.63
SZ11-3150/35 3.03 24.6 7.0 0.90 2.6 9.77 0.72
SZ11-4000/35 3.63 29 7.0 0.90 2.85 11.97 0.78
SZ11-5000/35 4.35 34 7.0 0.80 3.26 13.55 0.85
SZ11 -6300/35 5.28 36.6 7.5 0.80 3.78 16.17 0.86
SZ11-8000/35

35 ±

3x2.5%

38.5±

3x2.5%

10.5

6.3

Ynd11 7.38 40 7.5 0.70 4.73 18.7 0.9
SZ11-10000/35 8.7 47.8 7.5 0.70 4.83 20.3 1
SZ11-12500/35 10.26 56.6 8.0 0.60 6.2 26.1 1.2
SZ11-16000/35 12.2 59.1 8.0 0.60 8.3 34.2 2
SZ11-20000/35 14.5 83.5 8.0 0.60 8.6 38.5 2.1
SZ11-25000/35 17.1 98.8 8.0 0.55 8.9 42.3 2.2
SZ11-31500/35 20.3 118.5 8.0 0.55 9.2 44.8 2.3

 Three Phase Oil Immersed On-Load Power Transformers Operating Conditions

  • Ambient Temperature Condition:Oil Immersed On-Load Power Transformers shall be used in an environment where the maximum ambient temperature does not exceed 40℃, and the minimum ambient temperature is not lower than -25℃. For areas with extreme low temperatures below -25℃, low-temperature resistant transformer oil should be configured to ensure the fluidity of the oil medium and the normal operation of Oil Immersed On-Load Power Transformers.
  • Ambient Humidity Condition:Oil Immersed On-Load Power Transformers are suitable for environments with a relative humidity not exceeding 90% (at 25℃, no condensation). The fully sealed structure of Oil Immersed On-Load Power Transformers can effectively resist moisture erosion, making it applicable to humid scenarios such as coastal industrial zones and underground substations.
  • Environmental Cleanliness Condition:Oil Immersed On-Load Power Transformers allow operation in environments with moderate dust, but it is strictly prohibited to use them in places with heavy dust accumulation, corrosive gases or flammable and explosive vapors. For dusty working conditions such as metallurgy and mining, simple dust-proof shielding measures should be taken for Oil Immersed On-Load Power Transformers to prevent dust from entering the internal components and affecting insulation performance.
  • Power System Condition:Oil Immersed On-Load Power Transformers are applicable to AC 50Hz (or 60Hz according to customization) power systems, and the system voltage fluctuation shall not exceed ±5% of the rated voltage of the transformer. The on-load tap-changing function of Oil Immersed On-Load Power Transformers can only be activated under the condition of matching the system load, avoiding frequent tap switching that may cause mechanical wear of the equipment.

 

Documentation Resource Library
Dimension and installation for S11-XXXX/36 Oil-immersed distribution transformers
Restricted.
Dimension and installation for S11-XXXX/36 Oil-immersed distribution transformers
Drawing
English
Consulting
Consulting
Vziman IEC/ ANSI Oil-immersed Power transformer selection catalog
Restricted.
Vziman IEC/ ANSI Oil-immersed Power transformer selection catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: How does the on-load tap-changer (OLTC) mechanism work in your power transformers, and what are its maintenance requirements?
A:

The on-load power transformers feature a robust tap-changer mechanism that physically switches between transformer winding taps while energized, adjusting the output voltage in real-time to compensate for load variations or grid fluctuations. While designed for durability with minimal maintenance, regular oil analysis and periodic inspection of the OLTC contacts are recommended as part of a preventive maintenance schedule to ensure long-term reliability and performance of the transformer.

Q: What are the key benefits of using a Three-Phase Oil-Immersed On-Load Tap-Changing (OLTC) Power Transformer applications?
A:

Our on-load power transformers provide critical operational flexibility and enhanced power quality. They allow voltage regulation without interrupting the power supply, which is essential for maintaining grid stability, supporting sensitive industrial processes, and improving overall system efficiency. The oil-immersed design ensures effective cooling and insulation, making these 35kV/38.5kV units highly reliable for continuous, demanding operations.

Related Products

Related Solutions

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.