| Brand | Vziman |
| Model NO. | Customization Oil Immersed distribution Transformer 27kV 33kV 34.5kV 35kV |
| Rated voltage | 27kV |
| Rated frequency | 50/60Hz |
| Rated capacity | 160kVA |
| Series | S11 |
Oil-Immersed distribution Transformer Product Introduction
This 160 KVA Three phase distribution Transformer is a high-performance Oil-Immersed distribution Transformer with a dedicated 11kV to 0.4kV step-down design, boasting a rated capacity of 160 KVA, 11kV primary voltage and 0.4kV secondary voltage, perfectly meeting medium and low-voltage power distribution demands of power grid systems. This Oil-Immersed distribution Transformer adopts a fully sealed structure equipped with corrugated plate radiators, which can automatically expand and shrink with ambient temperature changes to ensure stable heat dissipation; the corrugated tank of the Three phase distribution Transformer also features a sleek appearance and compact size, saving installation space for on-site application. Engineered with advanced technology and high-quality raw materials and core components, this Oil-Immersed distribution Transformer delivers reliable product quality and long-term stable operation. Vziman implements strict full acceptance testing for every delivered piece of equipment, and has maintained a 0 fault rate record for more than 10 years; our Three phase distribution Transformer fully complies with IEC, ANSI and other major international standards, with standardized technical parameters to adapt to global power grid application requirements.
Oil-Immersed distribution Transformer Core Features
Three phase distribution Transformer Scope of Supply
Technical Specification
160 KVA transformer specifications and data sheet
|
Model |
S11-160 KVA-11/0.4KV |
|
Type |
Oil Immersed Distribution Transformer |
|
Standard |
IEC60076 |
|
Rated Power |
160 KVA |
|
Frequency |
50 HZ |
|
Phase |
Three |
|
Cooling Type |
ONAN |
|
Primary Voltage |
11 KV |
|
Secondary Voltage |
0.4 KV |
|
Winding Material |
Copper |
|
Vector Group |
Dyn11 |
|
Impedance |
4% |
|
Tap Changer |
NLTC |
|
Tapping Range |
±2*2.5% |
|
No Load Loss |
0.29KW |
|
On Load Loss |
2.2KW |
|
Accessories |
Standard Configuration |
Application Scenario: Urban and Rural Residential Area Power Distribution
160 KVA 11/0.4KV Transformer Winding

The applications of transformer winding
It can rise or lower the level of level of Voltage or Current in an AC Circuit.
It can increase or decrease the value of capacitor, an inductor or resistance in an AC circuit.
It can be used to prevent DC from passing from one circuit to the other.
It can isolate two circuits electrically.
Finished 160 KVA 11/0.4KV Transformer