LV Pole-mounted circuit break Description
The LV Pole-mounted circuit break D265T is a dedicated protection device for rural MV/LV transformer systems, specially engineered to adapt to significant load imbalance scenarios and ensure full utilization of installed power even under unbalanced operating conditions. The D265T circuit break features a 4-pole (3 protected) structure and adopts advanced air-break technology with metal partition arc-extinguishing chambers, which effectively cuts the arc during operation and provides reliable protection for 50 kVA or 100 kVA transformers. Equipped with a digital trip unit, the LV Pole-mounted circuit break D265T realizes precise and intelligent protection control for transformer systems, solving the core pain points of rural power grid transformer protection and management.
D265T circuit break Benefits
- The D265T circuit break offers more compact structure and easier operation for transformer protection compared with traditional fused solutions, simplifying on-site installation and daily maintenance of the LV Pole-mounted circuit break.
- When the D265T circuit break is closed, a built-in spark gap limits the LV neutral potential rise from the earth for values exceeding 10 kV, effectively protecting the transformer and associated power grid equipment from overvoltage damage.
- When the D265T circuit break is open, it automatically establishes an electrical connection between the transformer neutral and the ground, further enhancing the operational safety of the power system where the LV Pole-mounted circuit break is applied.
- Customizable solutions for the LV Pole-mounted circuit break D265T are available—contact us to tailor configurations according to your actual needs, including feeder quantity, fixing support, rod assembly type, trip unit type, load indicator option and more for the D265T circuit break.
Stadards: HN 63-S-11
D265T circuit break Electrical Values
| Rated Voltage(Ur) |
0.44kV |
| Rated Current |
265A |
| Rated short-circuit breaking capacity |
6.4kA |
| Rated short-circuit making current |
11.7kA |
| Rated short-time withstand current(1s) |
6.4kA/S |
| Rated power-frequency withstand voltage(50HZ-1 min) |
10kV |
| Lighting impulse withstand level of ovtage(1.2/50) |
20kV |
D265T circuit break Features
| Degree of protection |
IP31 |
| Number of outputs |
1 |
| Conductor size |
50-150mm² |
D265T circuit break Temperatures
| Operating temperature |
-25...50°C |
| Storage temperature |
-25...70°C |
D265T circuit break Application Scenario
Rural Power Grid MV/LV Transformer Protection
The LV Pole-mounted circuit break D265T is the core protection equipment for rural power grid pole-mounted 50 kVA/100 kVA MV/LV transformers, widely deployed in rural residential areas, rural agricultural production zones and rural township industrial small parks. Aimed at the characteristics of rural power grids such as scattered load distribution, frequent load imbalances and complex on-site operating conditions, the D265T circuit break provides stable and reliable arc-extinguishing and overcurrent/overvoltage protection for pole-mounted transformers, ensures continuous and stable power supply for rural daily electricity, agricultural production and small-scale industrial operation, and optimizes the protection and management efficiency of rural power grid transformer systems.