| Brand | Vziman |
| Model NO. | 500kV 250MVA Single-phase Three-winding Auto-Transformer |
| Rated capacity | 300MVA |
| No-load loss | 80kW |
| Series | ODFPSZ |
500kV Single-phase Three-winding Auto-Transformer Product Introduction
The 500kV Single-phase Three-winding Auto-Transformer, as a core energy conversion equipment in ultra-high voltage power systems, with a rated capacity of 250MVA, accurately meets the requirements of large-capacity and long-distance power transmission. It is a preferred core equipment for national hub substations and external power transmission projects of large energy bases. This 500kV Single-phase Three-winding Auto-Transformer realizes efficient conversion and dispatching of multi-voltage level electric energy relying on its core structure of single-phase three-winding autotransformer, perfectly connecting the 500kV high-voltage power grid with medium and low-voltage distribution networks, and providing stable support for inter-regional power grid interconnection.
500kV Single-phase Three-winding Auto-Transformer Advantages
500kV Single-phase Three-winding Auto-Transformer Technical Parameters
(1) 500kV 100MVA~484MVA Single-phase, Double-winding Power Transformer with Off-circuit Tap-changer
| Rated Capacity (MVA) | Vector Group | Efficiency Level I | Efficiency Level II | Efficiency Level III | Short-Circuit Impedance (%) | |||||
| HV Tap Range (%) | LV (kV) | No-Load Loss (kW) | Load Loss (kW) | No-Load Loss (kW) | Load Loss (kW) | No-Load Loss (kW) | Load Loss (kW) | |||
| 100 |
500/√3 525/√3 535/√3 550/√3 |
13.8; 15.75 | li0 | 34 | 203 | 40 | 203 | 49 | 214 | 14 |
| 120 | 15.75; 18; 20 | 39 | 234 | 46 | 234 | 56 | 247 | |||
| 200 | 15.75; 18; 20; 24 | 63 | 342 | 74 | 342 | 91 | 361 | |||
| 223 | 18 | 68 | 371 | 81 | 371 | 99 | 391 | |||
| 240 | 18; 20; 24 | 72 | 392 | 85 | 392 | 105 | 413 | |||
| 260 | 18; 20 | 77 | 414 | 91 | 414 | 112 | 437 | |||
| 380 | 24; 27 | 102 | 549 | 121 | 549 | 149 | 580 | 16 or 18 | ||
| 400 | 106 | 570 | 125 | 570 | 154 | 601 | ||||
| 410 | 108 | 581 | 128 | 581 | 158 | 613 | ||||
| 484 | 123 | 657 | 145 | 657 | 178 | 694 | ||||
Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.
(2) 500kV 120MVA~1170MVA Three-phase, Double-winding Power Transformer with Off-circuit Tap-changer
| Rated Capacity (MVA) | Vector Group | Efficiency Level I | Efficiency Level II | Efficiency Level III | Short-Circuit Impedance (%) | |||||
| HV Tap Range (%) | LV (kV) | No-Load Loss (kW) | Load Loss (kW) | No-Load Loss (kW) | Load Loss (kW) | No-Load Loss (kW) | Load Loss (kW) | |||
| 120 |
500 525 550 |
13.8; 15.75 | YNd11 | 41 | 356 | 49 | 356 | 60 | 375 | 14 |
| 160 | 50 | 441 | 59 | 441 | 72 | 466 | ||||
| 240 | 69 | 599 | 81 | 599 | 100 | 632 | ||||
| 300 | 13.8; 15.75;18 | 80 | 707 | 94 | 707 | 116 | 746 | |||
| 370 | 15.75; 18; 20 | 94 | 810 | 111 | 810 | 136 | 855 | |||
| 400 | 18; 20; 24 | 96 | 855 | 114 | 855 | 140 | 903 | |||
| 420 | 15.75; 18; 20; 20 | 102 | 860 | 120 | 860 | 148 | 907 | 14 or 16 |
||
| 480 | 15.75; 18; 20; 20 | 110 | 954 | 130 | 954 | 160 | 1007 | |||
| 600 | 15.75; 18; 20; 24 | 143 | 1202 | 169 | 1202 | 208 | 1268 | |||
| 720 | 18; 20; 24 | 168 | 1382 | 198 | 1382 | 244 | 1458 | |||
| 750 | 20; 22 | 173 | 1422 | 205 | 1422 | 252 | 1501 | 16 or 18 |
||
| 780 | 22 | 176 | 1467 | 208 | 1467 | 256 | 1549 | |||
| 860 | 190 | 1575 | 224 | 1575 | 276 | 1663 | ||||
| 1140 | 27 | 237 | 1949 | 280 | 1949 | 344 | 2057 | |||
| 1170 | 242 | 1980 | 286 | 1980 | 352 | 2090 | ||||
Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.
Thanks to the structural characteristics of autotransformers, the 500kV Single-phase Three-winding Auto-Transformer realizes direct power transmission through the common winding section. Compared with conventional two-winding transformers of the same capacity, it reduces copper and iron losses by 10%–20% in both no-load and load conditions, greatly cutting long-term grid energy consumption.
Q: Why is the 500kV Single-phase Three-winding Auto-Transformer more suitable for complex terrain transportation?
A: Compared with integral three-phase transformers, the 500kV Single-phase Three-winding Auto-Transformer is smaller in size and lighter in weight, which solves the transportation restrictions of ultra-high voltage three-phase transformers and adapts to complex terrains such as mountains and hills.
Q: How does the 500kV Single-phase Three-winding Auto-Transformer ensure low failure rate and high operational reliability?
A: Its windings are made of oxygen-free copper conductors with rigid binding structures and precision insulation design, which can withstand electromagnetic force impacts during short-circuit faults. The iron core uses high-quality grain-oriented silicon steel sheets with a multi-step structure, effectively reducing hysteresis loss and noise, ensuring stable operation under 500kV conditions.
Q: What are the advantages of the 500kV Single-phase Three-winding Auto-Transformer in engineering construction?
A: The 500kV Single-phase Three-winding Auto-Transformer can be transported in batches and assembled on site, which greatly lowers engineering construction difficulty and transportation costs, and is especially suitable for external power transmission projects of large energy bases.