500kV 250MVA Single-phase Three-winding Auto-Transformer

  • 500kV 250MVA Single-phase Three-winding Auto-Transformer
Key attributes
Brand Vziman
Model NO. 500kV 250MVA Single-phase Three-winding Auto-Transformer
Rated capacity 120MVA
No-load loss 41kW
Series ODFPSZ
Product descriptions from the supplier
Description

500kV Single-phase Three-winding Auto-Transformer Product Introduction 

The 500kV Single-phase Three-winding Auto-Transformer, as a core energy conversion equipment in ultra-high voltage power systems, with a rated capacity of 250MVA, accurately meets the requirements of large-capacity and long-distance power transmission. It is a preferred core equipment for national hub substations and external power transmission projects of large energy bases. This 500kV Single-phase Three-winding Auto-Transformer realizes efficient conversion and dispatching of multi-voltage level electric energy relying on its core structure of single-phase three-winding autotransformer, perfectly connecting the 500kV high-voltage power grid with medium and low-voltage distribution networks, and providing stable support for inter-regional power grid interconnection.

500kV Single-phase Three-winding Auto-Transformer Advantages

  • High power conversion efficiency & low-loss energy saving:The structural characteristics of the autotransformer enable direct power transmission through its common winding section. Compared with conventional two-winding transformers of the same capacity, it significantly reduces copper and iron losses by 10%–20% in both no-load and load conditions. Long-term operation can greatly cut power grid energy consumption, aligning with the requirements of green and low-carbon power grid construction.
  • Single-phase structure facilitates transportation and on-site deployment:Compared with integral three-phase transformers, single-phase units are smaller in size and lighter in weight, making them adaptable to transportation conditions in complex terrains such as mountainous and hilly areas, and solving the transportation restrictions of ultra-high voltage three-phase transformers. Meanwhile, single-phase equipment can be transported in batches and assembled on site, which greatly lowers engineering construction difficulty and transportation costs, and is especially suitable for external power transmission projects of large energy bases.
  • Strong short-circuit withstand capacity & high operational reliability:The windings are made of oxygen-free copper conductors, combined with rigid binding structures and precision insulation design, which can withstand the huge electromagnetic force impact during grid short-circuit faults. The iron core is made of high-quality grain-oriented silicon steel sheets, and its multi-step structure effectively reduces hysteresis loss and noise. It ensures long-term stable operation of the equipment under 500kV ultra-high voltage conditions with a low failure rate.

500kV Single-phase Three-winding Auto-Transformer Technical Parameters

(1) 500kV 100MVA~484MVA Single-phase, Double-winding Power Transformer with Off-circuit Tap-changer

Rated Capacity (MVA)   Vector Group Efficiency Level I Efficiency Level II Efficiency Level III Short-Circuit Impedance (%)
HV Tap Range (%) LV (kV) No-Load Loss (kW) Load Loss (kW) No-Load Loss (kW) Load Loss (kW) No-Load Loss (kW) Load Loss (kW)
100

500/√3

525/√3

535/√3

550/√3

13.8; 15.75 li0 34 203 40 203 49 214 14
120 15.75; 18; 20 39 234 46 234 56 247
200 15.75; 18; 20; 24 63  342 74 342 91 361
223 18 68 371 81 371 99 391
240 18; 20; 24 72 392 85 392 105 413
260 18; 20 77 414 91 414 112 437
380  24; 27 102 549 121 549 149 580 16 or 18
400 106 570 125  570 154 601
410 108 581 128 581 158 613
484 123 657 145  657 178 694

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

(2) 500kV 120MVA~1170MVA Three-phase, Double-winding Power Transformer with Off-circuit Tap-changer

Rated Capacity (MVA)   Vector Group Efficiency Level I Efficiency Level II Efficiency Level III Short-Circuit Impedance (%)
HV Tap Range (%) LV (kV) No-Load Loss (kW) Load Loss (kW) No-Load Loss (kW) Load Loss (kW) No-Load Loss (kW) Load Loss (kW)
120

500

525

550

13.8; 15.75 YNd11 41 356 49 356 60 375 14
160 50 441 59 441 72 466
240 69 599 81 599 100 632
300 13.8; 15.75;18 80 707 94 707 116 746
370 15.75; 18; 20 94 810 111 810 136 855
400 18; 20; 24 96 855 114 855 140 903
420 15.75; 18; 20; 20 102 860 120 860 148 907 14 or 16
480 15.75; 18; 20; 20 110 954 130 954 160 1007
600 15.75; 18; 20; 24 143 1202 169 1202 208 1268
720 18; 20; 24 168  1382 198 1382 244 1458
750 20; 22 173 1422 205 1422 252 1501

16 or 18

780 22 176 1467 208 1467 256 1549
860 190 1575 224 1575 276 1663
1140 27 237 1949 280 1949 344 2057
1170 242 1980 286 1980 352 2090

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

Documentation Resource Library
Globalized Extra HV Distribution Transformer selection catalog
Restricted.
Globalized Extra HV Distribution Transformer selection catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What advantages does the 500kV Single-phase Three-winding Auto-Transformer have in terms of energy saving?
A:

Thanks to the structural characteristics of autotransformers, the 500kV Single-phase Three-winding Auto-Transformer realizes direct power transmission through the common winding section. Compared with conventional two-winding transformers of the same capacity, it reduces copper and iron losses by 10%–20% in both no-load and load conditions, greatly cutting long-term grid energy consumption.

Q: Why is the 500kV Single-phase Three-winding Auto-Transformer more suitable for complex terrain transportation?

A: Compared with integral three-phase transformers, the 500kV Single-phase Three-winding Auto-Transformer is smaller in size and lighter in weight, which solves the transportation restrictions of ultra-high voltage three-phase transformers and adapts to complex terrains such as mountains and hills.

Q: How does the 500kV Single-phase Three-winding Auto-Transformer ensure low failure rate and high operational reliability?

A: Its windings are made of oxygen-free copper conductors with rigid binding structures and precision insulation design, which can withstand electromagnetic force impacts during short-circuit faults. The iron core uses high-quality grain-oriented silicon steel sheets with a multi-step structure, effectively reducing hysteresis loss and noise, ensuring stable operation under 500kV conditions.

Q: What are the advantages of the 500kV Single-phase Three-winding Auto-Transformer in engineering construction?

A: The 500kV Single-phase Three-winding Auto-Transformer can be transported in batches and assembled on site, which greatly lowers engineering construction difficulty and transportation costs, and is especially suitable for external power transmission projects of large energy bases.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.